Objectives

  • Upgrade ESXi host to 9.0 using vLCM image-based lifecycle management
  • Understand vSphere-to-VVF conversion requirements and pre-checks
  • Assign VVF license to upgraded host and verify entitlements
  • Differentiate the VVF 9 primary license (VMware vSphere Foundation, cores) from add-on licenses (vSAN TiB capacity) and from pre-9 license keys still used for ESX 8.x hosts
  • Handle license expiry: 90-day evaluation, the 90-day post-expiry update window, and the 180-day usage report

Prerequisites

VVF lab with vCenter deployed and at least one ESXi host running a prior version (or simulated via snapshot)

Prior labs: vvf-support-01

Required skills:

  • vCenter UI navigation
  • SSH to ESXi
  • vLCM basics

Lab Environment

Holodeck vSphere Foundation 9.0 instance (New-HoloDeckInstance -VVF). Holodeck deploys VVF at 9.0.0.0 or later only, so it cannot provide an ESX 8.x host: for the upgrade exercise add a nested ESX 8.0 U3 host built outside Holodeck to the cluster, or run Tasks 1-2 as a walkthrough.

Credentials

SystemUsernamePassword
vCenteradministrator@vsphere.localHolodeck documented default (Post Deployment table)
Nested ESX hostsrootHolodeck documented default (Post Deployment table)

Tasks

Task 1 Pre-Upgrade Compatibility Check and vLCM Image Setup

manageability

vLCM image-based management is the supported upgrade path for VVF 9.0. Understanding pre-checks prevents upgrade failures — a core support skill.

Step 1

vCenter UI → Lifecycle Manager → Images. Review existing image definitions. Note current ESXi version on target host.

The image depot lists the ESX 9.0 base image and vendor add-ons; the cluster image check shows the 8.x host as non-compliant. (vLCM baselines were removed in vCenter 9.0 — VCF 9.0.1 docs p.226.)
Step 2

Create or verify ESX 9.0 image: Click 'New Image' → select ESX 9.0 depot → add vendor add-on (e.g., HPE/Dell) if applicable → add any required firmware add-ons.

ESX 9.0 image created with base image + optional vendor add-on.
Step 3

Navigate to target host → Configure → Image. Click 'Check Compliance'. Review compliance report for hardware compatibility warnings.

Compliance check returns either 'Compliant' or lists specific incompatibilities (drivers, firmware).
Step 4

If non-compliant: review Hardware Compatibility List (HCL) for the specific server model. Document which components need driver updates.

Exam tests knowledge of HCL check before upgrade. Always verify CPU, NIC, and storage controller compatibility.
Step 5

Place host in maintenance mode: Right-click host → Maintenance Mode → Enter. For vSAN, select 'Ensure data accessibility' evacuation mode.

Host enters maintenance mode. All VMs migrated via DRS (or manually if DRS disabled).

Validation Gate

Check: Host is in maintenance mode, vLCM image compliance check completed

Expected: Host shows 'Maintenance Mode' status. Compliance report generated.

Common Errors

Compliance check shows 'Incompatible' for NIC driver
Cause: Driver in current image not certified for ESX 9.0
Fix: Add updated driver component to the vLCM image before remediation.
Host won't enter maintenance mode — vSAN objects inaccessible
Cause: Insufficient capacity on remaining hosts for vSAN data evacuation
Fix: In a three-host cluster with FTT=1 RAID-1 there is no spare fault domain for a full evacuation: use 'Ensure accessibility' for a planned upgrade and keep the maintenance window short. Check vSAN health for capacity warnings.

Task 2 Remediate Host with vLCM Image (ESXi Upgrade)

manageability

vLCM remediation is the actual upgrade mechanism. Understanding the workflow, monitoring progress, and troubleshooting failures is essential for support.

Step 1

With host in maintenance mode → Configure → Image → Click 'Remediate'. Select single-host remediation.

Remediation wizard starts. Pre-check validation runs automatically.
Step 2

Review pre-remediation checks: firmware compatibility, available disk space (>2GB on boot device), network connectivity. Accept and proceed.

Pre-checks pass. Remediation begins — host reboots into upgrade mode.
Step 3

Monitor remediation progress in vCenter Tasks panel. Note the stages: staging → pre-check → install → reboot → post-check.

Typical upgrade takes 15-30 minutes. If stuck at 'staging' for >10 minutes, check /var/log/lifecycle.log on the host (vLCM image operations — VCF 9.0.1 docs p.246) and the vCenter task details.
Step 4

After remediation completes, verify: Host → Summary → ESXi version should show 9.0.x. Check Configure → Image → Compliance = 'Compliant'.

ESXi version updated to 9.0.x. Image compliance shows green checkmark.
Step 5

Exit maintenance mode: Right-click host → Exit Maintenance Mode. Verify VMs are migrated back (DRS) or manually power on.

Host exits maintenance mode. DRS rebalances VMs across cluster.

Validation Gate

Check: ESXi host upgraded to 9.0 and operational

Expected: esxcli system version get returns 9.0.x. Host is out of maintenance mode with VMs running.

Common Errors

Remediation fails at 'staging' phase
Cause: Insufficient boot device space or network timeout downloading image
Fix: Check boot device free space (esxcli storage filesystem list). Verify vCenter can reach depot URL. Do not install VIBs by hand on a host in an image-managed cluster — it creates image drift; fix depot access or boot-device space and re-run remediation.
Host fails to reboot after upgrade
Cause: Incompatible driver or firmware causing boot failure
Fix: Reboot and press Shift+R when the hypervisor progress bar starts to revert to the previous bootbank image (Broadcom KB 316592); then check /var/log/lifecycle.log and vmkernel.log, fix the image (driver or firmware add-on) and remediate again. Alt+F1 only opens the local console.

Task 3 Assign VVF License and Verify Entitlements

manageability

VVF 9.0 licensing is subscription-based with one primary license — VMware vSphere Foundation (cores) — plus add-on licenses such as vSAN (TiB); there are no Standard/Advanced/Enterprise VVF tiers (VCF 9.0.1 docs p.1458). Licenses are assigned in VCF Operations to vCenter instances and the components are licensed automatically. Understanding assignment, usage reporting and expiry is critical for Obj 5.4.

Step 1

In VCF Operations open License Management > Licenses and select the Version 9+ tab (VCF Operations must be registered with the VCF Business Services console, connected or disconnected mode — check under License Management > Registration). Review the licenses present: the primary VMware vSphere Foundation (cores) license and the VMware vSAN (TiB) add-on. Note any component still in evaluation mode — evaluation lasts up to 90 days (VCF 9.0.1 docs p.1463; a 9.0.1 known issue shows 60 days in the ESX/Installer UI).

License inventory shows the primary and add-on licenses with capacity (cores, TiB) and expiry dates.
Step 2

Add license capacity: in the VCF Business Services console (vcf.broadcom.com) the default license holds the subscribed capacity; in VCF Operations add the license with available capacity. There is no per-component key — one primary license covers vSphere, vSAN and vCenter for vSphere Foundation.

Pre-9 license keys (e.g. 'VMware vSphere 8 Enterprise Plus') are only used for ESX 8.x hosts that have not been upgraded; the Version 9 equivalent table on p.1461 maps them to the single VVF (cores) license.
Step 3

Assign the license: in VCF Operations assign the VMware vSphere Foundation (cores) license to the vCenter instance. The ESX hosts and other components under that vCenter are licensed automatically; then assign the vSAN (TiB) add-on if the cluster uses vSAN.

The vCenter instance shows the VVF primary license assigned; hosts move from Evaluation to licensed; vSAN capacity is covered by the add-on.
Step 4

Verify usage: review the core count (vSphere 9.0 counts a minimum of 16 cores per CPU, p.80) and the vSAN TiB usage against the subscribed capacity, and note the usage-report cadence — a usage report is required at least every 180 days (connected mode sends it automatically; disconnected mode uploads a usage file).

Core and TiB usage within capacity; next usage report date known.
Step 5

Understand expiry: evaluation lasts up to 90 days; when a license expires (subscription ended, or usage not reported and the license not refreshed within 180 days) you have 90 days to update it, with notifications in VCF Operations and vCenter. After those 90 days ESX hosts disconnect from vCenter, most host management operations are prevented and new workloads cannot be created or started; running workloads are not stopped (p.1458, p.1475). There is no 'License Expired' host state.

Exam tests the two 90-day windows (evaluation, post-expiry update) and the 180-day usage report — not a 30- or 60-day grace period.
Step 6

Document: compare the VVF 9 primary license (cores), the vSAN add-on (TiB) and version 8 license keys for not-yet-upgraded ESX hosts in a table: what each covers, where it is assigned (VCF Operations vs vCenter Licensing for 8.x keys), and how usage is reported.

Validation Gate

Check: VVF license assigned and entitlements verified

Expected: Host shows VVF license. Core and vSAN TiB usage within the subscribed capacity (there are no VVF tiers).

Common Errors

Trying to enter a license key for VVF 9
Cause: VVF 9 licensing is file/registration based in VCF Operations, not key based
Fix: VVF 9 has no license keys (VCF 9.0.1 docs p.1457): add the license in VCF Operations (connected mode from the VCF Business Services console, or a license file in disconnected mode) and assign it to the vCenter instance. Keys apply only to ESX 8.x hosts that are still licensed in vCenter.
Features not available after license assignment
Cause: The primary license was not assigned to the vCenter instance in VCF Operations (components are licensed only through the vCenter assignment), or the vSAN add-on capacity is missing
Fix: Assign the VMware vSphere Foundation (cores) license to the vCenter instance in VCF Operations, then the vSAN (TiB) add-on; confirm the usage report has been submitted within 180 days.

Final Validation

ESXi host upgraded to 9.0 via vLCM and VVF license assigned with correct entitlements

✓ ESXi version is 9.0.x → esxcli system version get returns ESX 9.0.x

✓ vLCM image compliance is green → Configure → Image shows 'Compliant'

✓ VVF license assigned → vCenter shows the VMware vSphere Foundation (cores) license assigned, hosts licensed, and the vSAN TiB add-on applied

✓ Host operational → VMs running, vSAN healthy, no alarms

Cleanup / Restore

• Revert to pre-upgrade snapshot if needed for subsequent labs

• Leave the VCF Operations license assignment in place; record the next usage-report date

Design Reflection (VCDX)

Upgrade sequencing is a critical design decision. In production, rolling upgrades must consider vSAN fault domains, DRS admission control, and N+1 capacity during maintenance windows.

Requirements

  • Upgrade ESXi to 9.0 with zero VM downtime
  • Maintain vSAN data availability during upgrade

Constraints

  • Holodeck environment has limited hosts — full data migration may not be possible
  • Boot device size limits image staging

Assumptions

  • Hardware is on VVF 9.0 HCL
  • Sufficient cluster capacity for maintenance mode evacuation

Risks

  • Boot failure after upgrade requires physical console access
  • vSAN rebuild after maintenance mode exit impacts cluster performance

Self-Assessment Discussion Prompts

  1. Why must you use 'Ensure data accessibility' vs 'Full data migration' for vSAN evacuation in a 3-node cluster?
  2. What happens to running VMs if a host fails to reboot after vLCM remediation?
  3. How does VVF subscription licensing differ from legacy perpetual vSphere licensing?

Extensions

Upgrade all 3 hosts in sequence — practice rolling upgrade workflow

Review the 180-day usage-report reminder and the expiry notifications in VCF Operations (do not move system clocks forward — that breaks certificates and vSAN)

Explain why vCenter 9.0 offers images only (baselines removed, p.226) and how a baseline-managed 8.x cluster is converted to images before the upgrade

⚠ Known Pitfalls

Never upgrade ESXi without checking vLCM image compliance first — incompatible drivers cause boot failures
vSAN data evacuation in 3-node cluster: use 'Ensure accessibility' not 'Full migration' (insufficient capacity)
VVF is licensed per core (minimum 16 cores per CPU counted), not per socket — verify the core count reported in VCF Operations stays within the subscribed capacity